JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 34 No. 4 671-678
© 1993 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cherry, S. R.
Right arrow Articles by Hoffman, E. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cherry, S. R.
Right arrow Articles by Hoffman, E. J.

Correction and Characterization of Scattered Events in Three-Dimensional PET Using Scanners with Retractable Septa

Simon R. Cherry, Steven R. Meikle and Edward J. Hoffman

The Crump Institute and the Division of Nuclear Medicine and Biophysics, UCLA School of Medicine, Los Angeles, California
Department of Nuclear Medicine, Royal Prince Alfred Hospital, Sydney, Australia

Correspondence: For reprints or correspondence contact: Simon R. Cherry, Division of Nuclear Medicine & Biophysics, UCLA School of Medicine, Los Angeles, CA 90024-1721.

ABSTRACT

Large sensitivity increases are realized in positron emission tomography when the interplane septa are removed and all lines of response acquired. Unfortunately, three-dimensional acquisition results in a large increase in scatter fraction which prevents accurate quantitation. By acquiring short two-dimensional scans prior to three-dimensional ones, scatter distributions can be estimated from differences between lines of response common to both data sets. This initial scatter distribution can be further modified to approximate scatter in the entire three-dimensional dataset. The method was validated with phantom measurements in which absolute activity concentrations were known in all compartments. Following scatter correction, a four-compartment phantom that was nonuniform in activity and density, both axially and transaxially, gave activity concentrations of 0.45 ± 0.02, 0.31 ± 0.02, 0.01 ± 0.01 and 0.01 ± 0.01 µCi/cc for compartments containing 0.43, 0.29, 0.0 (air) and 0.0 (water) µCi/cc, respectively. Thus, scatter distributions for complex sources can be estimated from image data without lengthy Monte-Carlo simulations. When activity distributions vary slowly with time, this method can be used to correct for scatter in three-dimensional patient studies.




This article has been cited by other articles:


Home page
JNMHome page
C. Lartizien, C. Comtat, P. E. Kinahan, N. Ferreira, B. Bendriem, and R. Trebossen
Optimization of Injected Dose Based on Noise Equivalent Count Rates for 2- and 3-Dimensional Whole-Body PET
J. Nucl. Med., September 1, 2002; 43(9): 1268 - 1278.
[Abstract] [Full Text] [PDF]


Home page
NeoReviewsHome page
C. H. Contag, S. Fraser, and R. Weissleder
Strategies in In Vivo Molecular Imaging
NeoReviews, December 1, 2000; 1(12): e225 - 232.
[Full Text]


Home page
BrainHome page
J. S. Rakshi, T. Uema, K. Ito, D. L. Bailey, P. K. Morrish, J. Ashburner, A. Dagher, I. H. Jenkins, K. J. Friston, and D. J. Brooks
Frontal, midbrain and striatal dopaminergic function in early and advanced Parkinson's disease A 3D [18F]dopa-PET study
Brain, September 1, 1999; 122(9): 1637 - 1650.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1993 by the Society of Nuclear Medicine.