JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 34 No. 3 469-473
© 1993 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Williams, C. C.
Right arrow Articles by Clanton, J. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Williams, C. C.
Right arrow Articles by Clanton, J. A.

The Bacterial Endotoxin Test in the PET Facility

Craig C. Williams, Ronald D. Borchert and Jeffrey A. Clanton

The Christ Hospital, Metabolic Imaging Center, Cincinnati, Ohio
Nuclear Medicine-PET, Kettering Medical Center, Kettering, Ohio
Nuclear Medicine-PET, Vanderbilt University, Nashville, Tennessee

Correspondence: For correspondence or reprints contact: Craig Williams, Metabolic Imaging Center, Christ Hospital, 2139 Auburn Ave., Cincinnati OH 45219.

ABSTRACT

A method by which the gel-clot Limulus amebocyte lysate test may be performed in 20 rather than 60 min with sufficient sensitivity to satisfy the needs of the nuclear medicine or positron emission tomography laboratories has been developed and validated for use as a substitute for the Bacterial Endotoxin Test described in the United States Pharmacopeia, 22nd revision. Using this method, results may be obtained from the test prior to the human administration of radiopharmaceuticals without extensive loss of activity and with increased safety when compared to tests performed after administration. Additionally, studies on the shelf-lives of the reagents used in the test were conducted. When refrigerated between use, control standard endotoxin dilutions of 5 EU/ml or greater may be used for at least 1 mo after preparation and reconstituted lysate retains its labeled sensitivity for at least 10 days, considerably longer than the manufacturer's stated shelf-lives.




This article has been cited by other articles:


Home page
JNMHome page
S. Yaghoubi, J. R. Barrio, M. Dahlbom, M. Iyer, M. Namavari, N. Satyamurthy, R. Goldman, H. R. Herschman, M. E. Phelps, and S. S. Gambhir
Human Pharmacokinetic and Dosimetry Studies of [18F]FHBG: A Reporter Probe for Imaging Herpes Simplex Virus Type-1 Thymidine Kinase Reporter Gene Expression
J. Nucl. Med., August 1, 2001; 42(8): 1225 - 1234.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS