JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 34 No. 11 2019-2024
© 1993 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rusinek, H.
Right arrow Articles by de Leon, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rusinek, H.
Right arrow Articles by de Leon, M. J.

Principal Axes and Surface Fitting Methods for Three-Dimensional Image Registration

Henry Rusinek, Wai-Hon Tsui, Alejandro V. Levy, Marilyn E. Noz and Mony J. de Leon

Departments of Radiology and Psychiatry, New York University Medical Center, New York, New York
N.S. Kline Institute for Psychiatric Research, Orangeburg, NY
Brookhaven National Laboratory, Upton, New York

Correspondence: For correspondence or reprints contact: Henry Rusinek, PhD, Dept. of Radiology, Bellevue C Bldg., Rm D120, New York University Medical Center, New York, NY 10016.

ABSTRACT

We evaluated the effect of the image acquisition parameters on the accuracy of the principal axes and surface-fitting techniques for three-dimensional image registration. Using two types of phantom objects, MR brain image and a mathematically defined ellipsoid, we simulated pairs of scans with known acquisition parameters, including longitudinal coverage, magnitude of misregistration, number of sections and section thickness. Both methods are sensitive to the systematic deformation of contours. The principal axes method is also sensitive to incomplete scan coverage and to the x-axis and y-axis misangulation. Both methods are insensitive to the number of sections, section thickness and the number of points per section. Surface fitting performed well without user supervision. There is no need for routine inclusion of the scaling factors as search parameters. The results confirm the feasibility of three-dimensional multimodality registration of brain scans with accuracy 1–2 mm, with surface fitting being the method of choice.




This article has been cited by other articles:


Home page
StrokeHome page
M. Wintermark, A. E. Flanders, B. Velthuis, R. Meuli, M. van Leeuwen, D. Goldsher, C. Pineda, J. Serena, I. v. d. Schaaf, A. Waaijer, et al.
Perfusion-CT Assessment of Infarct Core and Penumbra: Receiver Operating Characteristic Curve Analysis in 130 Patients Suspected of Acute Hemispheric Stroke
Stroke, April 1, 2006; 37(4): 979 - 985.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child.Home page
R O Robinson, C D Ferrie, M Capra, and M N Maisey
Positron emission tomography and the central nervous system
Arch. Dis. Child., September 1, 1999; 81(3): 263 - 270.
[Full Text]


Home page
Am. J. PsychiatryHome page
E. J. Bartlett, J. D. Brodie, P. Simkowitz, S. L. Dewey, J.-P. Lindenmayer, H. Rusinek, A. Wolkin, R. Cancro, and W. Schiffer
Effect of a Haloperidol Challenge on Regional Brain Metabolism in Neuroleptic-Responsive and Nonresponsive Schizophrenic Patients
Am J Psychiatry, March 1, 1998; 155(3): 337 - 343.
[Abstract] [Full Text]


Home page
J. Clin. Endocrinol. Metab.Home page
M. J. de Leon, T. McRae, H. Rusinek, A. Convit, S. De Santi, C. Tarshish, J. Golomb, N. Volkow, K. Daisley, N. Orentreich, et al.
Cortisol Reduces Hippocampal Glucose Metabolism in Normal Elderly, but Not in Alzheimer's Disease
J. Clin. Endocrinol. Metab., October 1, 1997; 82(10): 3251 - 3259.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1993 by the Society of Nuclear Medicine.