JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 34 No. 1 137-142
© 1993 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bettinardi, V.
Right arrow Articles by Fazio, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bettinardi, V.
Right arrow Articles by Fazio, F.

A Procedure for Patient Repositioning and Compensation for Misalignment Between Transmission and Emission Data in PET Heart Studies

Valentino Bettinardi, Maria Carla Gilardi, Giovanni Lucignani, Claudio Landoni, Giovanna Rizzo, Giuseppe Striano and Ferruccio Fazio

INB-CNR, Scientific Institute H. San Raffaele and University of Milan, Milan, Italy

Correspondence: For reprints or correspondence contact: Dr. V. Bettinardi, Department of Nuclear Medicine, Scientific Institute H. San Raffaele, Via Olgettina 60, 20132, Milan, Italy.

ABSTRACT

A procedure for patient repositioning and compensation for misalignment between transmission and emission data in positron emission tomography (PET) heart studies has been developed. Following the transmission scan (TR1), patients are moved from the scanner bed for the administration of the tracer, and repositioned when ready for the emission scan (EM1). A short postinjection transmission scan (TR2) is performed at the end of the EM1 study. TR1 and TR2 images are compared to recognize misalignment between transmission and emission studies. TR1 sinograms are compensated for misalignment to allow for a proper attenuation correction. The procedure has been tested on phantom and [18F]FDG PET heart studies. Misalignments down to 2.5 mm translation and 1 degree rotation in the transaxial plane and 4 mm in the axial direction can be recognized and compensated for. The procedure is suitable for clinical purposes, allowing reduction of patient time on the scanner bed, increased patient comfort and significant increase of patient throughput.

FOOTNOTES

Editor's Note: A related article by Bacharach et al. will appear in the February issue.




This article has been cited by other articles:


Home page
JNMHome page
M. F. Di Carli, S. Dorbala, J. Meserve, G. El Fakhri, A. Sitek, and S. C. Moore
Clinical Myocardial Perfusion PET/CT
J. Nucl. Med., May 1, 2007; 48(5): 783 - 793.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. Loghin, S. Sdringola, and K. L. Gould
Common Artifacts in PET Myocardial Perfusion Images Due to Attenuation-Emission Misregistration: Clinical Significance, Causes, and Solutions
J. Nucl. Med., June 1, 2004; 45(6): 1029 - 1039.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1993 by the Society of Nuclear Medicine.