JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 33 No. 9 1620-1622
© 1992 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Taylor, A.
Right arrow Articles by Folks, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Taylor, A., Jr.
Right arrow Articles by Folks, R.

Prospective Validation of a Single Sample Technique To Determine Technetium-99m-MAG3 Clearance

Andrew Taylor, Jr., Patti Corrigan, Dennis Eshima and Russell Folks

Department of Radiology, Emory University Medical Center, Atlanta, Georgia
University of New Mexico, Albuquerque, New Mexico

Correspondence: For reprints contact: Andrew Taylor, Jr., MD, Emory University Hospital, Department of Radiology, 1364 Clifton Rd., N.E., Atlanta, GA 30322.

ABSTRACT

Technetium-99m-MAG3 clearance is proportional to OIH clearance and can be used directly as a measure of renal function. Multiple plasma sample, two-compartment clearance data from three studies were recently pooled to develop a single-sample regression equation for determining the clearance of 99mTc-MAG3. To test this published equation, a prospective study was conducted in 34 patients with a wide range of renal function. Multiple plasma samples were obtained from 9 to 60 min following the bolus injection of 99mTc-MAG3 and the clearances were calculated based on a single injection, two-compartment model. Clearances were also calculated using a single 43-min plasma sample and the published regression equation. There was an excellent correlation (r = 0.976) between the two clearances; the slope of the regression line was 1.01 with an intercept of –26.6; the standard error of the estimate was 24 ml/mm. In conclusion, the current regression equation provides a good estimate of 99mTc-MAG3 clearance.