JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 33 No. 4 605-612
© 1992 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by King, M.A.
Right arrow Articles by Glick, S.J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by King, M.A.
Right arrow Articles by Glick, S.J.

A Dual-Photopeak Window Method for Scatter Correction

M.A. King, G.J. Hademenos and S.J. Glick

Department of Nuclear Medicine, University of Massachusetts Medical School, Worcester, Massachusetts

Correspondence: For reprints contact: Michael A. King, PhD, Department of Nuclear Medicine, University of Massachusetts Medical Center, 55 Lake Avenue North, Worcester, MA 01655.

ABSTRACT

The imaging of scattered photons degrades contrast and is a major source of error in the quantitation of activity. It was hypothesized that, if the photopeak was divided into two nonoverlapping energy windows, a regression relation could be obtained between the ratio of counts within these windows and the scatter fraction for counts within the total region. This idea was tested by acquiring dual photopeak window acquisitions of a 99mTc point source in an elliptical attenuator, and at the same locations in air. From these, a regression between the scatter fraction and window ratio was determined. When this regression was applied to estimate the scatter distribution for acquisitions in both uniform and nonuniform elliptical attenuators, the residual scatter fraction was reduced approximately ten-fold and the estimated scatter line spread functions matched very closely the tails of the total line spread functions. In SPECT acquisitions, dual-photopeak window scatter correction was observed to significantly increase the contrast of "cold" spheres, improve the accuracy of estimating activity at the center of "hot" spheres, and return the three-dimensional modulation transfer function for point sources in an elliptical attenuator to near their in-air shape.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1992 by the Society of Nuclear Medicine.