The Journal of Nuclear Medicine Vol. 33 No. 12 2238-2245
© 1992 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Frey, E. C.
Right arrow Articles by Perry, J. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Frey, E. C.
Right arrow Articles by Perry, J. R.

Simultaneous Acquisition of Emission and Transmission Data for Improved Thallium-201 Cardiac SPECT Imaging Using a Technetium-99m Transmission Source

Eric C. Frey, Benjamin M.W. Tsui and J. Randolph Perry

Department of Biomedical Engineering and Department of Radiology, The University of North Carolina at Chapel Hill, North Carolina

Correspondence: For reprints contact: Eric C. Frey, PhD, Department of Biomedical Engineering, The University of North Carolina, 144 MacNider Hall, CB 7575, Chapel Hill, NC 27599.

ABSTRACT

Transmission computed tomography (TCT) data provides useful complementary information to single-photon emission computed tomography (SPECT) reconstructions, especially for cardiac studies. In particular, TCT data has been used to correct for nonuniform attenuation in the chest. Typically the transmission data are acquired in a separate acquisition, but simultaneous acquisition is preferable both to save time and to avoid difficulties involved with registration. In this work, we present a technique for simultaneously acquiring 201Tl SPECT and TCT data using a 99mTc sheet source that requires only minor equipment modifications. The use of these isotopes results in cross-contamination of the emission and transmission data. We present a practical technique to compensate for this contamination using postacquisition image processing. This technique was evaluated by performing phantom and patient studies. The resulting images compare well with data obtained from separate emission and transmission studies.




This article has been cited by other articles:


Home page
JNMHome page
F. Harel, R. Genin, D. Daou, R. Lebtahi, N. Delahaye, B. O. Helal, D. Le Guludec, and M. Faraggi
Clinical Impact of Combination of Scatter, Attenuation Correction, and Depth-Dependent Resolution Recovery for 201Tl Studies
J. Nucl. Med., October 1, 2001; 42(10): 1451 - 1456.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. P. Ficaro, J. A. Fessler, P. D. Shreve, J. N. Kritzman, P. A. Rose, and J. R. Corbett
Simultaneous Transmission/Emission Myocardial Perfusion Tomography : Diagnostic Accuracy of Attenuation-Corrected 99mTc-SestamibiSingle-Photon Emission Computed Tomography
Circulation, February 1, 1996; 93(3): 463 - 473.
[Abstract] [Full Text]