JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 32 No. 1 37-43
© 1991 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Broadhurst, P.
Right arrow Articles by Lahiri, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Broadhurst, P.
Right arrow Articles by Lahiri, A.

Clinical Validation of a Miniature Nuclear Probe System for Continuous On-line Monitoring of Cardiac Function and ST-Segment

Paul Broadhurst, Peter Cashman, John Crawley, Edward Raftery and Avijit Lahiri

Department of Cardiology and Division of Clinical Sciences, Northwick Park Hospital and Clinical Research Centre, Watford Road, Harrow, Middlesex, United Kingdom

Correspondence: For reprints contact: Avijit Lahiri, MB, MSc, Department of Cardiology, Northwick Park Hospital, Watford Rd., Harrow HA1 3UJ, United Kingdom.

ABSTRACT

A new, miniature cesium iodide/photodiode nuclear probe (the "Cardioscint") has been developed for continuous online measurement of left ventricular function and the ST-segment. Ejection fraction (EF) measurements in 77 patients were compared with gated equilibrium radionuclide ventriculograms. The probe was positioned over the left ventricle by first using a blind positioning algorithm and then by using the gamma camera. Background was measured both manually and automatically. There was good correlation between probe (positioned blind) and gamma camera EF with both manual(r = 0.80, n = 65) and automatic (r = 0.78, n = 66) backgrounds. Use of the gamma camera did not significantly alter the results. Correlation between the probe stroke counts and thermodilution-derived stroke index during atrial pacing in six subjects was also satisfactory (r = 0.69, n = 102). Thus, the Cardioscint is able to provide a reliable estimate of EF and can track rapid changes in cardiac volumes.




This article has been cited by other articles:


Home page
CirculationHome page
S. Ismail, A. R. Jayaweera, G. Camarano, L. W. Gimple, E. R. Powers, and S. Kaul
Relation Between Air-Filled Albumin Microbubble and Red Blood Cell Rheology in the Human Myocardium: Influence of Echocardiographic Systems and Chest Wall Attenuation
Circulation, August 1, 1996; 94(3): 445 - 451.
[Abstract] [Full Text]


Home page
CirculationHome page
R. Belardinelli, D. Georgiou, G. Cianci, N. Berman, L. Ginzton, and A. Purcaro
Exercise Training Improves Left Ventricular Diastolic Filling in Patients With Dilated Cardiomyopathy : Clinical and Prognostic Implications
Circulation, June 1, 1995; 91(11): 2775 - 2784.
[Abstract] [Full Text]


Home page
NEJMHome page
B. L. Zaret and F. J. Wackers
Nuclear Cardiology- Second of Two Parts
N. Engl. J. Med., September 16, 1993; 329(12): 855 - 863.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1991 by the Society of Nuclear Medicine.