JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 31 No. 12 1899-1905
© 1990 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Go, R. T.
Right arrow Articles by Simpfendorfer, C. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Go, R. T.
Right arrow Articles by Simpfendorfer, C. C.

A Prospective Comparison of Rubidium-82 PET and Thallium-201 SPECT Myocardial Perfusion Imaging Utilizing a Single Dipyridamole Stress in the Diagnosis of Coronary Artery Disease

Raymundo T. Go, Thomas H. Marwick, William J. MacIntyre, Gopal B. Saha, Donald R. Neumann, Donald A. Underwood and Conrad C. Simpfendorfer

Departments of Nuclear Medicine and Cardiology, Cleveland Clinic Foundation, Cleveland, Ohio

Correspondence: For reprints contact: Raymundo T. Go, MD, Department of Nuclear Medicine, Gb3, Cleveland Clinic Foundation, 9500 Euclid Ave., Cleveland, OH 44195-5074.

ABSTRACT

The purpose of the present study is to prospectively compare myocardial perfusion imaging with rubidium-82 (82Rb) by positron emission tomography (PET) with thallium-201 (201Tl) imaging by single-photon emission tomography (SPECT) by recording both studies with a single dipyridamole handgrip stress, and reading both sets of images with the same display technique. In a series of 202 patients with previous coronary arteriography, the sensitivity, specificity, and accuracy of 82Rb PET were 93%, 78%, and 90% and for 201Tl SPECT 76%, 80%, and 77%, respectively. When 70 patients with previous therapeutic interventions were excluded, the remaining 132 patients showed a sensitivity, specificity, and accuracy of 95%, 82% and 92% for 82Rb PET and 79%, 76%, and 78% for 201Tl SPECT. The improved contrast resolution of PET resulted in markedly superior images and a more confident identification of defects.




This article has been cited by other articles:


Home page
J Am Coll Cardiol ImgHome page
S. Dorbala, R. Hachamovitch, Z. Curillova, D. Thomas, D. Vangala, R. Y. Kwong, and M. F. Di Carli
Incremental Prognostic Value of Gated Rb-82 Positron Emission Tomography Myocardial Perfusion Imaging Over Clinical Variables and Rest LVEF
J. Am. Coll. Cardiol. Img., July 1, 2009; 2(7): 846 - 854.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J Knuuti and F M Bengel
Positron emission tomography and molecular imaging
Heart, March 1, 2008; 94(3): 360 - 367.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. E. Merhige, W. J. Breen, V. Shelton, T. Houston, B. J. D'Arcy, and A. F. Perna
Impact of Myocardial Perfusion Imaging with PET and 82Rb on Downstream Invasive Procedure Utilization, Costs, and Outcomes in Coronary Disease Management
J. Nucl. Med., July 1, 2007; 48(7): 1069 - 1076.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. A. Santana, R. D. Folks, E. V. Garcia, L. Verdes, R. Sanyal, J. Hainer, M. F. Di Carli, and F. P. Esteves
Quantitative 82Rb PET/CT: Development and Validation of Myocardial Perfusion Database
J. Nucl. Med., July 1, 2007; 48(7): 1122 - 1128.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. F. Di Carli, S. Dorbala, J. Meserve, G. El Fakhri, A. Sitek, and S. C. Moore
Clinical Myocardial Perfusion PET/CT
J. Nucl. Med., May 1, 2007; 48(5): 783 - 793.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. F. Di Carli and R. Hachamovitch
New Technology for Noninvasive Evaluation of Coronary Artery Disease
Circulation, March 20, 2007; 115(11): 1464 - 1480.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
U. K. Sampson, S. Dorbala, A. Limaye, R. Kwong, and M. F. Di Carli
Diagnostic Accuracy of Rubidium-82 Myocardial Perfusion Imaging With Hybrid Positron Emission Tomography/Computed Tomography in the Detection of Coronary Artery Disease
J. Am. Coll. Cardiol., March 13, 2007; 49(10): 1052 - 1058.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
K. Yoshinaga, B. J.W. Chow, K. Williams, L. Chen, R. A. deKemp, L. Garrard, A. Lok-Tin Szeto, M. Aung, R. A. Davies, T. D. Ruddy, et al.
What is the Prognostic Value of Myocardial Perfusion Imaging Using Rubidium-82 Positron Emission Tomography?
J. Am. Coll. Cardiol., September 5, 2006; 48(5): 1029 - 1039.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. Schwaiger, S. Ziegler, and S. G. Nekolla
PET/CT: Challenge for Nuclear Cardiology
J. Nucl. Med., October 1, 2005; 46(10): 1664 - 1678.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
B. J.W. Chow, J. W. Wong, K. Yoshinaga, T. D. Ruddy, K. Williams, R. A. deKemp, J. DaSilva, and R. S. Beanlands
Prognostic Significance of Dipyridamole-Induced ST Depression in Patients with Normal 82Rb PET Myocardial Perfusion Imaging
J. Nucl. Med., July 1, 2005; 46(7): 1095 - 1101.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
B. J.W. Chow, K. Ananthasubramaniam, R. A. deKemp, M. M. Dalipaj, R. S.B. Beanlands, and T. D. Ruddy
Comparison of treadmill exercise versus dipyridamole stress with myocardial perfusion imaging using rubidium-82 positron emission tomography
J. Am. Coll. Cardiol., April 19, 2005; 45(8): 1227 - 1234.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C Y Loong and C Anagnostopoulos
Diagnosis of coronary artery disease by radionuclide myocardial perfusion imaging
Heart, August 1, 2004; 90(suppl_5): v2 - v9.
[Full Text] [PDF]


Home page
CirculationHome page
E. Nagel, C. Klein, I. Paetsch, S. Hettwer, B. Schnackenburg, K. Wegscheider, and E. Fleck
Magnetic Resonance Perfusion Measurements for the Noninvasive Detection of Coronary Artery Disease
Circulation, July 29, 2003; 108(4): 432 - 437.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Hernandez-Pampaloni, V. Allada, M. C. Fishbein, and H. R. Schelbert
Myocardial perfusion and viability by positron emission tomography in infants and children with coronary abnormalities: correlation with echocardiography,coronary angiography, and histopathology
J. Am. Coll. Cardiol., February 19, 2003; 41(4): 618 - 626.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
L. A. Diaz, R. C. Brunken, E. H. Blackstone, C. E. Snader, and M. S. Lauer
Independent contribution of myocardial perfusion defects to exercise capacity and heart rate recovery for prediction of all-cause mortality in patients with known or suspected coronary heart disease
J. Am. Coll. Cardiol., May 1, 2001; 37(6): 1558 - 1564.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
B Haluska, C Case, L Short, J Anderson, and T H Marwick
Effect of power Doppler and digital subtraction techniques on the comparison of myocardial contrast echocardiography with SPECT
Heart, May 1, 2001; 85(5): 549 - 555.
[Abstract] [Full Text]


Home page
CirculationHome page
S. Sdringola, D. Patel, and K. L. Gould
High Prevalence of Myocardial Perfusion Abnormalities on Positron Emission Tomography in Asymptomatic Persons With a Parent or Sibling With Coronary Artery Disease
Circulation, January 30, 2001; 103(4): 496 - 501.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
N. Al-Saadi, E. Nagel, M. Gross, A. Bornstedt, B. Schnackenburg, C. Klein, W. Klimek, H. Oswald, and E. Fleck
Noninvasive Detection of Myocardial Ischemia From Perfusion Reserve Based on Cardiovascular Magnetic Resonance
Circulation, March 28, 2000; 101(12): 1379 - 1383.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
A. Pasquet, M.S. Lauer, M.J. Williams, M.-A. Secknus, B. Lytle, and T.H. Marwick
Prediction of global left ventricular function after bypass surgery in patients with severe left ventricular dysfunction. Impact of pre-operative myocardial function, perfusion, and metabolism
Eur. Heart J., January 2, 2000; 21(2): 125 - 136.
[Abstract] [PDF]


Home page
NEJMHome page
C. R. Cole, E. H. Blackstone, F. J. Pashkow, C. E. Snader, and M. S. Lauer
Heart-Rate Recovery Immediately after Exercise as a Predictor of Mortality
N. Engl. J. Med., October 28, 1999; 341(18): 1351 - 1357.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
H. Jadvar, H. W. Strauss, and G. M. Segall
SPECT and PET in the Evaluation of Coronary Artery Disease
RadioGraphics, July 1, 1999; 19(4): 915 - 926.
[Abstract] [Full Text] [PDF]


Home page
ANN INTERN MEDHome page
A. M. Garber and N. A. Solomon
Cost-Effectiveness of Alternative Test Strategies for the Diagnosis of Coronary Artery Disease
Ann Intern Med, May 4, 1999; 130(9): 719 - 728.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. H. Marwick, C. Zuchowski, M. S. Lauer, M.-A. Secknus, M. J. Williams, and B. W. Lytle
Functional status and quality of life in patients with heart failure undergoing coronary bypass surgery after assessment of myocardial viability
J. Am. Coll. Cardiol., March 1, 1999; 33(3): 750 - 758.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
M. S. Lauer, G. S. Francis, P. M. Okin, F. J. Pashkow, C. E. Snader, and T. H. Marwick
Impaired Chronotropic Response to Exercise Stress Testing as a Predictor of Mortality
JAMA, February 10, 1999; 281(6): 524 - 529.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. Campisi, J. Czernin, H. Schoder, J. W. Sayre, F. D. Marengo, M. E. Phelps, and H. R. Schelbert
Effects of Long-term Smoking on Myocardial Blood Flow, Coronary Vasomotion, and Vasodilator Capacity
Circulation, July 14, 1998; 98(2): 119 - 125.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
M.G. Niemeyer, A.F.M. Kuijper, J.G. Meeder, M.J.M. Cramer, A.J.M. Cleophas, E.E. van der Wall, and M. G. Niemeyer
Comparison of Thallium Scintigraphy and Positron Emission Tomography
Angiology, October 1, 1997; 48(10): 843 - 853.
[Abstract] [PDF]


Home page
CirculationHome page
J. vom Dahl, O. Muzik, E. R. Wolfe Jr, C. Allman, G. Hutchins, and M. Schwaiger
Myocardial Rubidium-82 Tissue Kinetics Assessed by Dynamic Positron Emission Tomography as a Marker of Myocardial Cell Membrane Integrity and Viability
Circulation, January 15, 1996; 93(2): 238 - 245.
[Abstract] [Full Text]


Home page
CirculationHome page
J. Czernin, R. J. Barnard, K. T. Sun, J. Krivokapich, E. Nitzsche, D. Dorsey, M. E. Phelps, and H. R. Schelbert
Effect of Short-term Cardiovascular Conditioning and Low-Fat Diet on Myocardial Blood Flow and Flow Reserve
Circulation, July 15, 1995; 92(2): 197 - 204.
[Abstract] [Full Text]


Home page
CirculationHome page
J. Czernin, K. Sun, R. Brunken, M. Bottcher, M. Phelps, and H. Schelbert
Effect of Acute and Long-term Smoking on Myocardial Blood Flow and Flow Reserve
Circulation, June 15, 1995; 91(12): 2891 - 2897.
[Abstract] [Full Text]


Home page
CirculationHome page
R. E. Patterson, R. L. Eisner, and S. F. Horowitz
Comparison of Cost-Effectiveness and Utility of Exercise ECG, Single Photon Emission Computed Tomography, Positron Emission Tomography, and Coronary Angiography for Diagnosis of Coronary Artery Disease
Circulation, January 1, 1995; 91(1): 54 - 65.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1990 by the Society of Nuclear Medicine.