JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 31 No. 10 1635-1640
© 1990 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kung, H. F.
Right arrow Articles by Alavi, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kung, H. F.
Right arrow Articles by Alavi, A.

A New Myocardial Imaging Agent: Synthesis, Characterization, and Biodistribution of Gallium-68-BAT-TECH

H. F. Kung, B. L. Liu, D. Mankoff, M. P. Kung, J. J. Billings, L. Francesconi and A. Alavi

Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania

Correspondence: For reprints contact: Hank F. Kung, PhD, Division of Nuclear Medicine, Department of Radiology, University of Pennsylvania, 3400 Spruce St., Philadelphia, PA 19104.

ABSTRACT

In order to develop a new myocardial perfusion agent for positron emission tomography (PET), a new lipid-soluble gallium complex was evaluated. Synthesis, radiolabeling, characterization, and biodistribution of a unique gallium complex, [67Ga]BAT-TECH (bis-aminoethanethiol-tetraethyl-cyclohexyl), are described. The complex formation between Ga+3 and BAT-TECH ligand is simple, rapid, and of high yield (≥95%). This process is amenable to kit formulation. The complex has a net charge of +1 and a Ga/ligand ratio of 1:1. Biodistribution in rats shows high uptake in the heart as well as in the liver. When [68Ga] BAT-TECH was injected into a monkey, the heart and liver are clearly delineated by PET imaging, suggesting that this complex may be a possible tracer for myocardial perfusion imaging.




This article has been cited by other articles:


Home page
JNMHome page
G. L. Griffiths, C.-H. Chang, W. J. McBride, E. A. Rossi, A. Sheerin, G. R. Tejada, H. Karacay, R. M. Sharkey, I. D. Horak, H. J. Hansen, et al.
Reagents and Methods for PET Using Bispecific Antibody Pretargeting and 68Ga-Radiolabeled Bivalent Hapten-Peptide-Chelate Conjugates
J. Nucl. Med., January 1, 2004; 45(1): 30 - 39.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1990 by the Society of Nuclear Medicine.