JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 29 No. 8 1393-1397
© 1988 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cerqueira, M. D.
Right arrow Articles by Harp, G. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cerqueira, M. D.
Right arrow Articles by Harp, G. D.

The Influence of Collimators on SPECT Center of Rotation Measurements: Artifact Generation and Acceptance Testing

Manuel D. Cerqueira, Dale Matsuoka, James L. Ritchie and George D. Harp

Department of Radiology, Division of Nuclear Medicine, and the Department of Medicine, Division of Cardiology, Veterans Administration Medical Center and the University of Washington, Seattle, WA

Correspondence: For reprints contact: Manuel Cerqueira, MD, VA Medical Center, 1660 S. Columbian Way, Seattle, WA 98108

ABSTRACT

Misalignment between the electronic and mechanical axes of rotation will result in artifact generation and image degradation during single photon emission computed tomography (SPECT) reconstruction. Acceptance and quality control testing procedures have not emphasized the variability in center of rotation (COR) measurements caused by collimators and the need to verify uniformity across the full collimator field of view (FOV).Variation from the mean COR across the FOV was tested in four different collimators using multiple point source acquisitions. The mean COR was different for each collimator and two of the four had a >0.5 pixel difference from the mean COR on some area of the FOV. This variation makes these collimators unacceptable for SPECT acquisition. Thus, initial acceptance testing of SPECT collimators should verify a uniform COR across the full FOV and collimators with a variability from the mean COR>0.5 pixels should be rejected.