JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 29 No. 2 168-173
© 1988 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Seldin, D. W.
Right arrow Articles by Alderson, P. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Seldin, D. W.
Right arrow Articles by Alderson, P. O.

Comparison of Bone Density Measurements from Different Skeletal Sites

David W. Seldin, Peter D. Esser and Philip O. Alderson

Department of Radiology, Columbia University, New York, New York

Correspondence: For reprints contact: David W. Seldin, MD, Dept. of Radiology, Div. of Nuclear Medicine, 622 West 168 St., New York, NY 10032.

ABSTRACT

Absorptiometric measurements from multiple sites in 212 consecutive patients were examined to determine the interrelationships among bone mineral content values obtained from the lumbar spine, hip, and forearm. Dual photon absorptiometry was used to examine the spine, femoral neck, Ward's triangle, and greater trochanter while the radius and ulna were studied with single photon absorptiometry. All studies were performed on the same day. Concurrent measurements were available for the spine and hip in 197 patients, for the spine and forearm in 151 patients, and at all three sites for 146 patients. Variable degrees of correlation were found among the mineral content values from the six sites, with r values ranging from 0.40 to 0.93. The femoral neck and Ward's triangle showed the highest degree of correlation (r = 0.93); the ulna and lumbar spine demonstrated the poorest correlation (r = 0.40). Relationships between distant anatomic sites exhibited a large amount of variability (large standard error of the estimate) even when highly correlated. Useful predictions of bone mineral content could be obtained only for sites in close proximity. These results suggest that bone mineral content determinations in the upper extremities by single photon absorptiometry may not be useful for predicting mineralization in clinically more significant areas such as the lumbar spine and hip.