JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 28 No. 12 1820-1825
© 1987 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Clarke, S. E.M.
Right arrow Articles by Maisey, M. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Clarke, S. E.M.
Right arrow Articles by Maisey, M. N.

Scintigraphy and Treatment of Medullary Carcinoma of the Thyroid with Iodine-131 Metaiodobenzylguanidine

Susan E.M. Clarke, Colin R. Lazarus, Susan Edwards, Brian Murby, David G. Clarke, Theresa M. Roden, Ignac Fogelman and Michael N. Maisey

Department of Nuclear Medicine, and Department of Medical Physics, Guy's Hospital
Department of Radiotherapy, St. Thomas' Hospital, London

Correspondence: For reprints contact: Susan E.M. Clarke, MD, Dept. of Nuclear Medicine, Guy's Hospital, London SE1, United Kingdom.

ABSTRACT

We report our experience using [131I]metaiodobenzylguanidine (MIBG) to image nine patients with proven medullary carcinoma of the thyroid (MCT). Positive uptake was seen in four patients, equivocal uptake in one patient, and no uptake in four patients. Data is presented to demonstrate the pharmacokinetics of [131I]MIBG in three of the patients studied. Two patients, with diarrhea and severe pain from known bone metastases and positive uptake on [131I]MIBG diagnostic scanning, subsequently received therapeutic doses of [131I]MIBG, with marked improvement in both pain and diarrhea, but no evidence of significant biochemical response. Iodine-131 MIBG uptake in patients with MCT is variable, and gives a higher false-negative rate than is found when using [131I]MIBG to image other neuroectodermally derived tumors. The therapeutic potential of [131I]MIBG in patients with MCT warrants further evaluation, in view of the symptomatic relief experienced following therapy doses in two patients with extensive disease.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1987 by the Society of Nuclear Medicine.