JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 27 No. 12 1896-1901
© 1986 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chaly, T.
Right arrow Articles by Diksic, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chaly, T.
Right arrow Articles by Diksic, M.

High Yield Synthesis of 6-[18F]Fluoro-L-Dopa by Regioselective Fluorination of Protected L-Dopa with [18F]Acetylhypofluorite

Thomas Chaly and Mirko Diksic

Brain Imaging Centre, Montreal Neurological Institute and Hospital
Department of Neurology and Neurosurgery, McGill University, Montreal, Canada

Correspondence: For reprints contact: Mirko Diksic, PhD, Medical Cyclotron Unit, Montreal Neurological Institute, 3801 University St., Montreal, Quebec, H3A 2B4, Canada.

ABSTRACT

Regioselective fluorination of a completely protected phosgene derivative of 3,4-dihydrophenyl-L-alanine (5-(benzyl-3',4'-carbonate)-oxazolidine-2,5-dione) with gaseous 18F-labeled acetylhypofluorite and [18F]F2 in acetonitrile is described. Fluorination with [18F]acetylhypofluorite yields 6-[18F]fluoro-L-dopa with 95% radiochemical purity; fluorination of the same substrate with [18F]F2 yields a mixture of all three structural isomers in a ratio of 70:16:14 for 6-, 5-, and 2-fluoro compounds. Radiochemical yield, relative to [18F] acetylhypofluorite, measured at the end of the synthesis, is (21 ± 4)% (N = 8). The synthesis requires ~ 40 min (50 min if HPLC was done) and yields the final radiopharmaceutical in a two-step procedure. The specific activity of the final product was ~ 763 mCi/mmol at the end of a 40-min synthesis when 30-min irradiation was used.

FOOTNOTES

Presented at The Society of Nuclear Medicine Winter Meeting, Metabolic Imaging with NMR, SPECT and PET, March 3–5, 1986, West Palm Beach, FL.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1986 by the Society of Nuclear Medicine.