JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 27 No. 11 1669-1674
© 1986 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vallabhajosula, S.
Right arrow Articles by Fuster, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vallabhajosula, S.
Right arrow Articles by Fuster, V.

Indium-111 Platelet Kinetics in Normal Human Subjects: Tropolone Versus Oxine Methods

Shankar Vallabhajosula, Josef Machac, Stanley J. Goldsmith, Helena Lipszyc, Lina Badimon, Jacob Rand and Valentin Fuster

Departments of Physics-Nuclear Medicine and Medicine, Mount Sinai Medical Center, New York, New York

Correspondence: For reprints contact: Shankar Vallabhajosula, PhD, Andre Meyer Department of Physics-Nuclear Medicine, Mount Sinai Medical Center, One Gustave L. Levy Place, New York, NY 10029.

ABSTRACT

The effect of labeling media on the kinetics of [111In]platelets was evaluated by performing a paired crossover study in eight normal human subjects using tropolone and oxine methods. Platelets were labeled in autologous plasma with [111In]tropolone (In-tr) and in ACD-saline with [111]oxine (In-ox) and reinjected. Starting at 1 hr, ten blood samples were obtained over an 8-day period. The in vivo platelet recovery was higher at 1 hr and throughout the 8 days of study with In-tr and the gamma camera images showed less uptake in liver and spleen than with In-ox. When platelet life-span (PLS) was estimated using all ten samples, only linear regression showed that the platelet life-span was longer with In-tr (10.7 ± 1.5) than with In-ox (9.5 ± 0.8). When the PLS was estimated excluding the 1-hr sample point, the life-span of platelets was significantly longer with In-tr than with In-ox based on three out of four models of curve fitting. These results demonstrate that platelets labeled with In-tr in plasma are preserved better in circulation and have equal or longer life-span than platelets labeled with In-ox in ACD-saline.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1986 by the Society of Nuclear Medicine.