University of Medicine and Dentistry of New Jersey; Newark, New Jersey
University of Massachusetts; Amherst, Massachusetts
Correspondence: For reprints contact: Dandamudi V. Rao, PhD, Dept. of Radiology, University of Medicine and Dentistry of New Jersey, 100 Bergen St., Newark, NJ 07103.
ABSTRACT
When the Auger-electron emitter, 55Fe, and the beta-emitter, 59Fe, are similarly distributed in the testes of mice, the conventionally calculated average radiation dose to the organ from 55Fe is about 2.6 times more effective in reducing the sperm-head count than the dose from 59Fe. This finding emphasizes the ability of low-energy Auger electrons to damage radiosensitive targets of cells through localized irradiation. The observed efficacy is understandable in terms of dosimetric models based on intracellular distribution studies of the radionuclides.
This article has been cited by other articles:
![]() |
G. Grafstrom, B.-A. Jonsson, A. M. El Hassan, J. Tennvall, and S.-E. Strand Rat testis as a radiobiological in vivo model for radionuclides Radiat Prot Dosimetry, April 1, 2006; 118(1): 32 - 42. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |