Brookhaven National Laboratory, Upton, New York
Donner Laboratory, University of California, Berkeley, California
Correspondence: For reprints contact: Harold L. Atkins, Brookhaven National Laboratory, Associated Universities, Inc., Upton, NY 11973.
ABSTRACT
Studies were undertaken to determine the biologic distribution of thallium-201 in man. The disappearance from the blood is extremely rapid and intracellular deposition is nearly immediate. The biologic half-time of thallium was measured by both the Brookhaven whole-body counter and the Donner whole-body scanner, with excellent agreement. The effective whole-body half-time of thallium-201 is about 57 hr. Concentration of activity was seen in the heart, kidneys, large bowel, and thyroid. The whole-body radiation dose is 0.21 rads/mCi.
FOOTNOTES
* Present address: New England Nuclear Corp., North Billerica, MA 01862.
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |