JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 24 No. 3 197-203
© 1983 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meyer, J. H.
Right arrow Articles by Thomasson, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meyer, J. H.
Right arrow Articles by Thomasson, D.

Error and Corrections with Scintigraphic Measurement of Gastric Emptying of Solid Foods

J. H. Meyer, G. VanDeventer, L. S. Graham, J. Thomson and D. Thomasson

Veterans Administration Center, Sepulveda, California

Correspondence: For reprints contact: James H. Meyer, Dept. of Gastroenterology, VA Center, Selpulveda, CA 91343.

ABSTRACT

Previous methods for correction of depth used geometric means of simultaneously obtained anterior and posterior counts. The present study compares this method with a new one that uses computations of depth based on peak-to-scatter (P:S) ratios. Six normal volunteers were fed a meal of beef stew, water, and chicken liver that had been labeled in vivo with both In-113m and Tc-99m. Gastric emptying was followed at short intervals with anterior counts of peak and scattered radiation for each nuclide, as well as posteriorly collected peak counts from the gastric ROI. Depth of the nuclides was estimated by the P:S method as well as the older method. Both gave similar results. Errors from septal penetration or scatter proved to be a significantly larger problem than errors from changes in depth.




This article has been cited by other articles:


Home page
JNMHome page
H. A. Ziessman, F. H. Fahey, F. B. Atkins, and J. Tall
Standardization and Quantification of Radionuclide Solid Gastric-Emptying Studies
J. Nucl. Med., May 1, 2004; 45(5): 760 - 764.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. E. Spieth, B. S. Gauger, and T. C. Lauenstein
Time-Resolved 3D MRI of Gastric Emptying
Am. J. Roentgenol., January 1, 2004; 182(1): 259 - 259.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1983 by the Society of Nuclear Medicine.