JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 24 No. 12 1135-1142
© 1983 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kairento, A.-L.
Right arrow Articles by Elmaleh, D. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kairento, A.-L.
Right arrow Articles by Elmaleh, D. R.

Regional Blood-Flow Measurement in Rabbit Soft-Tissue Tumor with Positron Imaging Using the C15O2 Steady-State and Labeled Microspheres

A.-L. Kairento, G. L. Brownell, J. Schluederberg and D. R. Elmaleh

Massachusetts General Hospital, Boston, Massachusetts

Correspondence: For reprints contact: Dr. Gordon L. Brownell, Physics Research Laboratory, Massachusetts General Hospital, Fruit St., Boston, MA 02114.

ABSTRACT

The C15O2 steady-state method, with tomographic measurement of H215O, has been used to measure blood flow in normal muscle tissue and a soft-tissue tumor (V2) in rabbits. The method has been validated in a rabbit tumor model by comparison of the data with that observed using microspheres labeled with Sc-46 and Ga-68. The blood-flow values found with the C15O2 steady-state method, after correction for tissue blood volume, agree well with values gained with labeled microspheres. The effect of blood volume on apparent blood flow in tumor was about 50%. The tissue/blood partition coefficients were 0.94 ± 0.05 for healthy tissue and 1.16 ± 0.15 for tumor tissue. After correction for partition coefficient and blood-volume effects, the blood-flow value for normal tissue was 4.1 ± 1.3 ml/min-100 cc, and for the tumor tissue 10.7 ± ml/min-100 cc.




This article has been cited by other articles:


Home page
RadiologyHome page
G. Brix, M. L. Bahner, U. Hoffmann, A. Horvath, and W. Schreiber
Regional Blood Flow, Capillary Permeability, and Compartmental Volumes: Measurement with Dynamic CT—Initial Experience
Radiology, January 1, 1999; 210(1): 269 - 276.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1983 by the Society of Nuclear Medicine.