Massachusetts General Hospital, Boston, Massachusetts
Correspondence: For reprints contact: Dr. Gordon L. Brownell, Physics Research Laboratory, Massachusetts General Hospital, Fruit St., Boston, MA 02114.
ABSTRACT
The C15O2 steady-state method, with tomographic measurement of H215O, has been used to measure blood flow in normal muscle tissue and a soft-tissue tumor (V2) in rabbits. The method has been validated in a rabbit tumor model by comparison of the data with that observed using microspheres labeled with Sc-46 and Ga-68. The blood-flow values found with the C15O2 steady-state method, after correction for tissue blood volume, agree well with values gained with labeled microspheres. The effect of blood volume on apparent blood flow in tumor was about 50%. The tissue/blood partition coefficients were 0.94 ± 0.05 for healthy tissue and 1.16 ± 0.15 for tumor tissue. After correction for partition coefficient and blood-volume effects, the blood-flow value for normal tissue was 4.1 ± 1.3 ml/min-100 cc, and for the tumor tissue 10.7 ± ml/min-100 cc.
This article has been cited by other articles:
![]() |
G. Brix, M. L. Bahner, U. Hoffmann, A. Horvath, and W. Schreiber Regional Blood Flow, Capillary Permeability, and Compartmental Volumes: Measurement with Dynamic CT—Initial Experience Radiology, January 1, 1999; 210(1): 269 - 276. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |