JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 23 No. 9 823-829
© 1982 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Etani, H.
Right arrow Articles by Asai, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Etani, H.
Right arrow Articles by Asai, T.

Cerebral Perfusion Imaging with Albumin Microspheres Tagged with Tc-99m and In-111 in Cases with Internal Carotid Occlusion

Hideki Etani, Kazufumi Kimura, Shotaro Yoneda, Yoshiyasu Tsuda, Yoshinari Isaka, Masaichi Nakamura and Tsutomu Asai

Osaka University Medical School, Fukushima, 1.chome, Fukushima-ku, Osaka 553, Japan

Correspondence: For reprints contact: Hideki Etani, Div. of Nuclear Medicine, Osaka Univ. Med. School, Fukushima, 1 chome, Fukushima-ku, Osaka 553, Japan.

ABSTRACT

Cerebral perfusion imaging with dual-tracer (Tc-99m and In-111) human albumin microspheres (HAM scintigraphy) was performed in 15 cases with unilateral occlusion of the internal carotid artery, for the diagnosis and evaluation of collateral circulation patterns. After injection of Tc-99m microspheres into one common carotid artery and In-111 HAMs into the other, two perfusion images, one for each carotid artery, were clearly differentiated by appropriate pulse-height discrimination. With this method, diagnosis of internal carotid artery occlusion was definitely made in eight patients, suspected in six, and missed in one. The collateral perfusion areas from the contralateral ICA and ipsilateral external carotid artery were well demonstrated by this method, and the scintigraphic findings in all cases. Dual-tracer HAM scintigraphy is capable of adding information about collaterals at the capillary level to the anatomic information obtained by angiography.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1982 by the Society of Nuclear Medicine.