|
|
||||||||
University of Michigan Medical Center, Ann Arbor, Michigan
Correspondence: For reprints contact: Donald M. Wieland, PhD, Univ. of Michigan Hospital, 3685 Kresge I, Ann Arbor, MI 48109.
ABSTRACT
An evaluation of radioiodinated meta-iodobenzylguanidine (m-IBG) as an adrenomedullary imaging agent is reported in 15 rhesus monkeys. Scintiscans of the monkey adrenal medulla have been obtained with [123I]- and [m-131I]IBG at 26 days after injection. The imaging superiority of m-IBG over its positional isomer, para-iodobenzylguanidine (p-IBG), is documented in both dogs and monkeys. Administration of reserpine, a depletor of catecholamine stores, markedly lowers the [m-131I]-IBG content of the dog adrenal medulla, but the adrenergic blocking agents phenoxybenzamine and propranolol have no effect. Subcellular fractionation of the dog's adrenal medullae reveals that m-IBG is sequestered mainly in the chromaffin storage granules. The results of this study suggest that radioiodinated m-IBG, previously reported to image the primate myocardium, also merits evaluation as a clinical radiopharmaceutical for the adrenal medulla.
This article has been cited by other articles:
![]() |
G. H. Hinkle, J. V. Dura, R. S. Morosco, and M. C. Nahata Extended stability of iobenguane under simulated clinical conditions Am. J. Health Syst. Pharm., January 15, 2008; 65(2): 142 - 144. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. J. Akashi, K. Nakazawa, M. Sakakibara, F. Miyake, H. Musha, and K. Sasaka 123I-MIBG Myocardial Scintigraphy in Patients with "Takotsubo" Cardiomyopathy J. Nucl. Med., July 1, 2004; 45(7): 1121 - 1127. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Arao, N. Takabatake, M. Sata, S. Abe, Y. Shibata, T. Honma, K. Takahashi, A. Okada, Y. Takeishi, and I. Kubota In Vivo Evidence of Endothelial Injury in Chronic Obstructive Pulmonary Disease by Lung Scintigraphic Assessment of 123I-Metaiodobenzylguanidine J. Nucl. Med., November 1, 2003; 44(11): 1747 - 1754. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Pfluger, C. Schmied, U. Porn, G. Leinsinger, C. Vollmar, S. Dresel, I. Schmid, and K. Hahn Integrated Imaging Using MRI and 123| Metaiodobenzylguanidine Scintigraphy to Improve Sensitivity and Specificity in the Diagnosis of Pediatric Neuroblastoma Am. J. Roentgenol., October 1, 2003; 181(4): 1115 - 1124. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Zhao, N. Shuke, W. Yamamoto, A. Okizaki, J. Sato, Y. Ishikawa, T. Ohta, N. Hasebe, K. Kikuchi, and T. Aburano Comparison of Cardiac Sympathetic Nervous Function with Left Ventricular Function and Perfusion in Cardiomyopathies by 123I-MIBG SPECT and 99mTc-Tetrofosmin Electrocardiographically Gated SPECT J. Nucl. Med., July 1, 2001; 42(7): 1017 - 1024. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. van der Harst, W. W. de Herder, H. A. Bruining, H. J. Bonjer, R. R. de Krijger, S. W. J. Lamberts, A. H. van de Meiracker, F. Boomsma, T. Stijnen, E. P. Krenning, et al. [123I]Metaiodobenzylguanidine and [111In]Octreotide Uptake in Benign and Malignant Pheochromocytomas J. Clin. Endocrinol. Metab., February 1, 2001; 86(2): 685 - 693. [Abstract] [Full Text] |
||||
![]() |
S. Braune, M. Reinhardt, R. Schnitzer, A. Riedel, and C. H. Lucking Cardiac uptake of [123I]MIBG separates Parkinson's disease from multiple system atrophy Neurology, September 1, 1999; 53(5): 1020 - 1020. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |