JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 22 No. 11 1000-1005
© 1981 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lewis, S. E.
Right arrow Articles by Willerson, J. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lewis, S. E.
Right arrow Articles by Willerson, J. T.

Quantitation of Experimental Canine Infarct Size with Multipinhole and Rotating-Slanthole Tomography

Samuel E. Lewis, Ernest M. Stokely, Michael D. Devous, Sr., Frederick J. Bonte, L. Maximillian Buja, Robert W. Parkey and James T. Willerson

University of Texas Southwestern Medical School, Dallas, Texas

Correspondence: For reprints contact: Samuel E. Lewis, MD, University of Texas, Health Science Center, Dept. of Radiology, 5323 Harry Hines Blvd., Dallas, TX 75235.

ABSTRACT

Myocardial infarct size was estimated by three methods in a canine model, using Tc-99m pyrophosphate at 24 and 48 hr after coronary ligation. A gamma camera provided anterior, LAO, and lateral views, and was then fitted with multipinhole (MPH) and rotating-slanthole (RSH) collimators for tomographic studies, processed by computer to display frontal sections of the chest. Infarct weight was measured postmortem for comparison. All transmural infarcts were detected by all three imaging techniques. RSH tomography was superior to both MPH tomography and planar imaging for the detection of nontransmural infarction. Infarcts as small as 1.0 g were detected. Estimates of infarct volume measured from RSH slices showed an excellent correlation with infarct weight (r = 0.89) and were reproducible within acceptable limits. Estimates of infarct volume measured from MPH slices demonstrated a significantly poorer correlation with infarct weight (r = 0.48, p < 0.01). Both tomographic techniques may improve infarct visualization by suppressing overlying activity and increasing contrast between infarct and background, but both produce significant blur artifacts that hamper their utilization by inexprienced observers.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1981 by the Society of Nuclear Medicine.