JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 21 No. 9 821-828
© 1980 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Williams, D. L.
Right arrow Articles by Hamilton, G. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Williams, D. L.
Right arrow Articles by Hamilton, G. W.

In Vivo Simulation of Thallium-201 Myocardial Scintigraphy by Seven-Pinhole Emission Tomography

David L. Williams, James L. Ritchie, George D. Harp, James H. Caldwell and Glen W. Hamilton

Veterans Administration Medical Center, Seattle, Washington

Correspondence: For reprints contact: David L. Williams, PhD, Nuclear Medicine Section (115), VA Medical Ctr, 4435 Beacon Ave. S., Seattle, WA 98108.

ABSTRACT

Seven-pinhole emission tomography has been studied under conditions that simulate clinical myocardial imaging with thallium-201, and is compared with planar imaging with a heart phantom. The seven-pinhole technique produces reconstructed images that offer a tomographic presentation of the object but do not quantitatively represent true cross sections of the object's activity distribution. Tomography produces significantly greater image contrast than planar imaging, even when maximal background subtraction is used to enhance the planar images. Two quantitative limitations of seven-pinhole tomography are noted for a simulated 24-g, 1.5-cm-thick complete transmural infarct: (a) the defect's activity concentration is not accurately reconstructed, and (b) it propagates longitudinally into some reconstructed planes that do not contain it. The imaging limitations of seven-pinhole tomography under the conditions studied are shown to be consistent on several camera/computer/software configurations.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1980 by the Society of Nuclear Medicine.