JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 21 No. 7 679-681
© 1980 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Huang, C. C.
Right arrow Articles by Fordham, E. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Huang, C. C.
Right arrow Articles by Fordham, E. W.

In Vivo Stability and Distribution of [131I]Iodomethyl Trimethylammonium Chloride: Concise Communication

C. C. Huang, A. M. Friedman, G. V. S. Rayudu, P. Clark and E. W. Fordham

Argonne National Laboratory, Argonne, Illinois
Rush University Medical Center, Chicago, Illinois

Correspondence: For reprints contact: C. C. Huang, Chemistry Div., Argonne National Laboratory, 9700 S. Cass Ave., Argonne, IL 60439.

ABSTRACT

[131I]iodomethyl trimethylammonium chloride (I-131 TMA) was prepared by the isotope-exchange reaction of diiodomethane with Na131I, followed by reaction with trimethylamine. A specific activity of 20 µCl/mg was obtained.

issue distributions following intravenous injection of I-131 TMA in mice showed that between 10 min and 2 hr, the highest accumulations of radioactivity were in the urine, kideny, and heart. The uptake of this compound in the heart was very rapid, and the levels of radioactivity remained fairly high up to 2 hr. At 10, 30, 60, and 120 min the heart-to-blood ratios were, respectively, 10.2, 7.7, 8.3, and 9.6.

Thyroid uptake of this compound in the rats and analysis of urine samples of the mouse indicated no extensive deiodination of the compound in vivo.

These results show that this compound does have potential for use in myocardial imaging. In addition, its stability in vivo makes it very useful for the radiolabeling of compounds containing quaternary ammonium moieties.