JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 21 No. 6 579-592
© 1980 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Budinger, T. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Budinger, T. F.

Physical Attributes of Single-Photon Tomography

Thomas F. Budinger

Donner Laboratory, Lawrence Berkeley Laboratory, University of California, Berkeley, California

Correspondence: For reprints contact: Thomas F. Budinger, MD, PhD, Donner Laboratory, Lawrence Berkeley Laboratory, Univ. of California, Berkeley, CA 94720.

ABSTRACT

Physical properties important for assessment of the potentials of emission computed tomography implemented by collimated detector systems include sensitivity, statistical and angular sampling requirements, attenuation compensation, resolution uniformity, and multisection design constraints. The limited angular range and sampling interval of coded aperture methods for longitudinal tomography impose severe limitations on quantitative imaging capabilities. These methods are discussed. Disadvantages of limited angular range are avoided by transverse section devices that have lower sensitivity than comparable positron devices. It is shown here, however, that the sensitivity for a single section device for head transverse section 2 cm thick can be ~=200 events sec–1 µCi–1 per axial cm for 2 x 2 cm resolution. This is 40% of that for a well-designed positron system of similar resolution. The problem of attenuation compensation for constant attenuation, as in brain imaging, is well understood and a fast algorithm of the convolution type gives excellent results if angular sampling is over 360°.

Though there is a need to move the single-photon detector array over wide angular distances for adequate sampling, dynamic ECT is possible for the measurement of biological washout kinetics of clinical importance, such as clearance studies in brain. Based on physical principles, experiences with low sensitivity devices, and the prospects for devices with sensitivity comparable to positron tomographs, single photon tomography has sound potentials for research and clinical studies of the adult brain and whole body in small subjects. Practical whole-body tomography in adults is limited to nonquantitative lesion detection.




This article has been cited by other articles:


Home page
J. Nucl. Med. Technol.Home page
G. L. Zeng and P. E. Christian
Easy Method of Patient Positioning for Convergent-Beam Cardiac SPECT
J. Nucl. Med. Technol., September 1, 2007; 35(3): 131 - 134.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
N. Boussion, C. Houzard, K. Ostrowsky, P. Ryvlin, F. Mauguiere, and L. Cinotti
Automated Detection of Local Normalization Areas for Ictal-Interictal Subtraction Brain SPECT
J. Nucl. Med., November 1, 2002; 43(11): 1419 - 1425.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
M. W. Groch and W. D. Erwin
SPECT in the Year 2000: Basic Principles
J. Nucl. Med. Technol., December 1, 2000; 28(4): 233 - 244.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1980 by the Society of Nuclear Medicine.