JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 20 No. 12 1273-1278
© 1979 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McAfee, J. G.
Right arrow Articles by Smith, E. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McAfee, J. G.
Right arrow Articles by Smith, E. M.

Biological Distribution and Excretion of DTPA Labeled with Tc-99m and In-111

John G. McAfee1, George Gagne, Harold L. Atkins, Peter T. Kirchner, Richard C. Reba, M. Donald Blaufox and Edward M. Smith

Task Group—MIRD Committee

Correspondence: For reprints contact: John G. McAfee, Div. of Radiological Sciences/State Univ. of NY, Upstate Medical Center, 750 E. Adams St., Syracuse, NY 3210.

ABSTRACT

For the purpose of radiation dose estimates, organ assays and excretion measurements of the Tc-99m and In-111 complexes with DTPA were conducted in dogs at various time intervals up to 24 hr, and the results compared with available human data. The peak concentration of the Tc-99m complex, at 3 min after injection, was 5% of the administered dose for one kidney, 3.5% for the liver, and 3.5% for the small bowel. No organ system except the urinary tract reached a concentration higher than that in blood for several hours after the injection. The biliary excretion of these agents was extremely low, and their elimination in the feces was negligible. In man, it appears that the residual 4–5% of an administered dose not eliminated in the urine by 24 hr is widely distributed in various tissues. The distribution of the In-111 complex is similar but not identical to that of the Tc-99m complex.




This article has been cited by other articles:


Home page
JNMHome page
K. Itoh
Determination of Glomerular Filtration Rate by Means of Newly Developed Plastic Scintillation Counter Both With and Without Dilution Procedures
J. Nucl. Med., October 1, 2001; 42(10): 1484 - 1488.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1979 by the Society of Nuclear Medicine.