JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 20 No. 10 1075-1079
© 1979 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Neirinckx, R. D.
Right arrow Articles by Davis, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Neirinckx, R. D.
Right arrow Articles by Davis, M. A.

Potential Column Chromatography Generators for Ionic Ga-68. I. Inorganic Substrates

Rudi D. Neirinckx and Michael A. Davis

Harvard Medical School and Children's Hospital Medical Center, Boston, Massachusetts

Correspondence: For reprints contact: Rudi D. Neirinckx, Dept. of Radiology, Harvard Medical School, 25 Shattuck Street, Boston, MA 02115.

ABSTRACT

Chemical separations for Ga-68 from Ge-68 using adsorption chromatography on inorganic materials are described. The adsorbents used were TiO2, ZrO2, and SiO2. Distribution coefficients for Ge and Ga on these adsorbents were determined as a function of reagent concentration and duration of equilibration. The distribution coefficient (w/w) for Ge on SiO2 reached 250 in 6 N HNO3, whereas Ga was not significantly adsorbed. Therefore, Ga-68 can be collected with a small volume of 6 N HNO3 eluent. By contrast, large volumes of 1 N HNO3 were necessary to collect Ga-68 from ZrO2, since the KD of Ga under these circumstances was about 50. The Ga-68 eluted from TiO2 was chemically contaminated with titanates and would require additional chemical manipulation in order to make it injectable. All the adsorbents could lead to chromatographic systems that would allow acceptable chemical separations. However, the specific requirements for a radionuclide generator, usable in a hospital environment, make the SiO2-based system the most attractive.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1979 by the Society of Nuclear Medicine.