JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 19 No. 5 553-556
© 1978 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lewis, J. T.
Right arrow Articles by Bahr, G. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lewis, J. T.
Right arrow Articles by Bahr, G. H.

The Effect of Photon Energy on Tests of Field Uniformity in Scintillation Cameras: Concise Communication

Jeannine T. Lewis, Ralph A. Neff, Hiroshi Nishiyama and Gustave H. Bahr

Cincinnati General Hospital, Cincinnati, Ohio

Correspondence: For reprints contact: Jeannine T. Lewis, Nuclear Medicine Laboratory, Cincinnati General Hospital, Cincinnati, OH 45267.

ABSTRACT

Although Co-57 is generally used for testing the field uniformity of scintillation cameras, the various photon energies of other radionuclides require uniform response throughout the entire range of energies to which a scintillation camera can respond. The use of Co-57, however, may not adequately demonstrate the field response, which may be uniform at 122 keV but not at other energies. Two scintillation camera systems were investigated in this regard by storing field-flood images, obtained at several photon energies, in a minicomputer. The stored data were analyzed using the Kolmogorov-Smirnov test, revealing that field uniformity may change with photon energy. One of the scintillation cameras showed a variation in field response with photon energy, whereas the other camera did not. These results, however, should not be extrapolated to other cameras of the same type. If a particular scintillation camera is to be used routinely with several energies, its performance should be tested with each one to provide assurance that valid information is being obtained. The effects of dynamic uniformity field correction remain to be evaluated.