JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 18 No. 8 845-847
© 1977 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eichling, J. O.
Right arrow Articles by Ter-Pogossian, M. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eichling, J. O.
Right arrow Articles by Ter-Pogossian, M. M.

Determination of Radionuclide Concentrations with Positron CT Scanning (PETT): Concise Communication

J. O. Eichling, C. S. Higgins and M. M. Ter-Pogossian

Mallinckrodt Institute of Radiology, St. Louis, Missouri

Correspondence: For reprints contact: John Eichling, The Edward Mallinckrodt Institute, 510 S. Kingshighway Blvd., St. Louis, MO 63110.

ABSTRACT

A series of experiments was undertaken to evaluate the response of a positron emission transverse tomograph (PETT) to measured radionuclide concentrations similar to those encountered in human studies. The correlation between the response of the imaging system (mean PETT number/min), and the concentration of the radioactivity producing the output data, was linear with a computed sensitivity of 2720 PETT number/min, per µCi/ml, per picture element, for a radionuclide (100% ß+) contained in either of two phantoms and imaged with a resolution of 1.5 cm. It was concluded that the output data are essentially independent of the imaged object's physical dimensions for the range of 18–28-cm diam and faithfully reflect the regional radioactivity concentration within the object, provided valid attenuation correction is achieved and the sampled area is not compromised by the imaging system's limitations of spatial resolution.




This article has been cited by other articles:


Home page
JNMHome page
L. Geworski, B. O. Knoop, M. de Wit, V. Ivancevic, R. Bares, and D. L. Munz
Multicenter Comparison of Calibration and Cross Calibration of PET Scanners
J. Nucl. Med., May 1, 2002; 43(5): 635 - 639.
[Abstract] [Full Text] [PDF]


Home page
ScienceHome page
M. Raichle, M. Welch, R. Grubb Jr, C. Higgins, M. Ter-Pogossian, and K. Larson
Measurement of regional substrate utilization rates by emission tomography
Science, March 3, 1978; 199(4332): 986 - 987.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1977 by the Society of Nuclear Medicine.