JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 16 No. 8 780-786
© 1975 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goddard, B. A.
Right arrow Articles by Ackery, D. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goddard, B. A.
Right arrow Articles by Ackery, D. M.

Xenon-133, 127Xe, and 125Xe for Lung Function Investigations: A Dosimetric Comparison

B. A. Goddard and D. M. Ackery

Southampton General Hospital, Southampton, England

Correspondence: For reprints contact: Duncan Ackery, Wessex Regional Dept. of Nuclear Medicine, Southhampton General Hospital, Shirley, Southampton S09 4XY, England.

ABSTRACT

Of the possible radionuclides of xenon, 127Xe and 125Xe have better physical properties for lung function measurement than 133Xe. A comparison of the radiation doses for these three radionuclides has been made for a typical scintillation camera investigation. Using an exponential model for washin and washout of gas, it is shown that the specific activity-time relationship is always equal to the product of the spirometer concentration and the rebreathing period.

It is concluded that of the three radionuclides 127Xe gives the lowest radiation dose during a typical lung function study.




This article has been cited by other articles:


Home page
CirculationHome page
M. Apple, R. Waksman, R. C. Chan, Y. Vodovotz, J. Fournadjiev, and B. G. Bass
Radioactive 133-Xenon Gas-Filled Balloon to Prevent Restenosis: Dosimetry, Efficacy, and Safety Considerations
Circulation, August 6, 2002; 106(6): 725 - 729.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1975 by the Society of Nuclear Medicine.