JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 16 No. 8 744-755
© 1975 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Subramanian, G.
Right arrow Articles by Thomas, F. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Subramanian, G.
Right arrow Articles by Thomas, F. D.

Technetium-99m-Methylene Diphosphonate—A Superior Agent for Skeletal Imaging: Comparison with other Technetium Complexes

G. Subramanian, J. G. McAfee, R. J. Blair, F. A. Kallfelz and F. D. Thomas

Upstate Medical Center, State University of New York, Syracuse
New York State Veterinary College, Cornell University, Ithaca, New York

Correspondence: For reprints contact: Gopal Subramanian, Div. of Nuclear Medicine, Dept. of Radiology, Upstate Medical Center, State University of New York, Syracuse, N.Y. 13210.

ABSTRACT

Methylene diphosphonate (MDP) was formulated as a complex of 99mTc for skeletal imaging. This agent was compared with three other bone seeking technetium agents: ethane-1-hydroxy-1, 1-diphosphonate (EHDP), pyrophosphate, and polyphosphate. in tissue radioassay experiments in rodents, the technetium complexes of MDP and EHDP were similar, but skeletal concentration with both of these agents was higher than that with pyrophosphate or polyphosphate.

The total-body retention of MDP and EHDP complexed with 95mTc was studied in beagle dogs for 35 days by excretion measurements and total-body counting and compared with polyphosphate and pertechnetate. The long-term retention was greater for MDP. The 5-day cumulative fecal excretion of 95mTc was low when administered as EHDP or polyphosphate complexes and negligible when administered as MDP complex.

In six human volunteers the blood clearance of 99mTc-MDP was similar to that of 18F and significantly faster than that of 99mTc-EHDP. Pyrophosphate cleared from the blood much faster than polyphosphate but slower than the diphosphonates. The urinary excretion of the MDP complex was greater than for EHDP within the first 2–3 hr after injection. The 24-hr urinary excretion of pyrophosphate and polyphosphate complexes was not as complete as for the diphosphonates.

All four 99mTc complexes proved satisfactory for clinical imaging studies. The MDP complex produced images of superior quality as early as 2 hr after administration, attributable to its more rapid clearance from the blood and soft tissues. On the contrary, a longer interval of 3–4 hr after injection was usually needed for 99mTc-EHDP; pyrophosphate and polyphosphate complexes regularly required a waiting period of 4 hr.

Comparative radiation dose estimates were made based on the available biologic distribution data for these 99mTc skeletal-localizing agents.




This article has been cited by other articles:


Home page
JNMHome page
A. E.B. Moore, G. M. Blake, and I. Fogelman
Quantitative Measurements of Bone Remodeling Using 99mTc-Methylene Diphosphonate Bone Scans and Blood Sampling
J. Nucl. Med., March 1, 2008; 49(3): 375 - 382.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. Ogawa, T. Mukai, Y. Inoue, M. Ono, and H. Saji
Development of a Novel 99mTc-Chelate-Conjugated Bisphosphonate with High Affinity for Bone as a Bone Scintigraphic Agent
J. Nucl. Med., December 1, 2006; 47(12): 2042 - 2047.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. E.B. Moore, G. M. Blake, and I. Fogelman
Validation of a Blood-Sampling Method for the Measurement of 99mTc-Methylene Diphosphonate Skeletal Plasma Clearance
J. Nucl. Med., April 1, 2006; 47(4): 581 - 586.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. E.B. Moore, S. F. Hain, G. M. Blake, and I. Fogelman
Validation of Ultrafiltration as a Method of Measuring Free 99mTc-MDP
J. Nucl. Med., June 1, 2003; 44(6): 891 - 897.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
G. M. Blake, S.-J. Park-Holohan, and I. Fogelman
Quantitative Studies of Bone in Postmenopausal Women Using 18F-Fluoride and 99mTc-Methylene Diphosphonate
J. Nucl. Med., March 1, 2002; 43(3): 338 - 345.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1975 by the Society of Nuclear Medicine.