Veterans Administration Hospital and Medical College of Virginia, Richmond, Virginia
Correspondence: For reprints contact: Halcott T. Haden, Nuclear Medicine Section, V.A. Hospital and Medical College of Virginia, Richmond, Va. 23249.
ABSTRACT
Scintiphotographic studies in six patients with ureteral fistula following renal transplantation are presented. Images were obtained using 99mTc-Sn-DTPA or 131I-orthoiodohippurate. Urinary leakage was accurately detected in each case but the pattern of extravasation is highly variable. When carefully performed, radionuclide scintiphotography is a safe and effective method for detecting urinary leakage after renal transplantation.